My contact person
Select location

After selection of your ZIP code, we designate the relevant staff to attend to you at once.

chainflex® bus cable CFROBOT8

  • Requirements: For twistable applications 
  • Outer jacket: PUR 
  • Overall shield
  • Coolant resistant
  • Notch-resistant
  • Oil resistance: Oil-resistant according to DIN EN 50363-10-2 
  • Flame retardant
  • Hydrolysis and microbe-resistant
  • UV-resistant
  • chainflex® class: 6.1.3.3 
Product description
chainflex® bus cable CFROBOT8
 
Typical application areas
  • For extremely heavy duty applications with torsion movements
  • Almost unlimited resistance to oil, also with bio-oils
  • Indoor and outdoor applications, UV resistant
  • Especially for robots and 3D movements, handling, lead screw drives
Guaranteed service life for this series according to the guarantee conditions
More information: chainflex® Garanty
Cycles *  5 million7.5 million10 million
Temperature,v max. [°/s]a max. [°/s²]Torsion max.R min. [factor x d]R min. [factor x d]
from/to [°C]TwistedTwisted[°/m][°/m][°/m]
-25 / -15  ±150±90±30
-15 / +6018060±180±120±60
+60 / +70  ±150±90±30
* Higher number of cycles possible - please ask for your individual calculation.
 
Technical note bus cables
 
chainflex® bus cables are specially developed and tested for continuous use in e-chains® applications. Depending on
the used outer jacket material and the design principle, the bus cables are designed for different mechanical requirements
and media resistances.
The electrical design is selected in such a way that, on the one hand, the electrical properties of the respective bus specification are reliably fulfilled
, and the greatest importance is also placed on high EMC safety. A permanent stability of the
electrical values despite permanent movement is also ensured.
However, the entire transmission property in a complete bus communication system is not exclusively
dependent on the cable used. Rather, it requires an exact coordination of all components (electronic components,
connection technology and cable) as well as the consideration of the maximum transmission rates which are dependent on the respective systems
in relation to the required data transmission rates. A cable is therefore not solely responsible for the secure transmission of the
signals.
igus® advises you in the design of the appropriate bus system, taking into account all these factors and carrying out extensive tests to
ensure the process reliability of your system from the start.
 
 
Certificates and standards
UV resistance<br>High Silicone-free<br>Free from silicon which can affect paint adhesion (according to PV 3.10.7 – status 1992). EAC<br>Certified to no. TC RU C-DE. ME77.B.01218 CTP<br>Certified to no. C-DE.PB49.B.00416 Lead free<br>Following 2011/65/EU (RoHS-II) CEI<br>Following CEI 20-35 Clean room<br>According to ISO Class 1. Outer jacket material complies with CF27.07.05.02.01.D, tested by IPA according to standard 14644-1 CE<br>Following 2014/35/EU
Technical data
Downloads

Consulting

I would be happy to answer your questions personally

Shipping and consultation

In person:

Monday to Friday from 7 am - 8 pm.
Saturdays from 8 am- 12 pm.

Online:

24h